- Event A1 : Serving becomes better than threshold
- Event A2 : Serving becomes worse than threshold
- Event A3 : Neighbor becomes offset better than serving
- Event A4 : Neighbor becomes better than threshold
- Event A5 : Serving becomes worse than threshold1 and neighbor becomes better than threshold2
Event A1 (Serving becomes better than threshold)
Ms − Hys > Thresh (Entering condition)
Ms + Hys < Thresh (Leaving condition)
Ms + Hys < Thresh (Leaving condition)
Event A2 (Serving becomes worse than threshold)
Ms + Hys < Thresh (Entering condition)
Ms − Hys > Thresh Leaving condition
Ms − Hys > Thresh Leaving condition
Event A3 (Neighbor becomes offset better than serving)
Mn +Ofn +Ocn − Hys > Ms +Ofs +Ocs +Off (Entering condition)
Mn +Ofn +Ocn + Hys < Ms +Ofs +Ocs +Off (Leaving condition)
Mn +Ofn +Ocn + Hys < Ms +Ofs +Ocs +Off (Leaving condition)
Event A4 (Neighbor becomes better than threshold)
Mn +Ofn +Ocn− Hys > Thresh (Entering condition)
Mn +Ofn +Ocn + Hys < Thresh (Leaving condition)
Mn +Ofn +Ocn + Hys < Thresh (Leaving condition)
Event A5 (Serving becomes worse than threshold1 and neighbor becomes better than threshold2)
Ms + Hys < Thresh1 AND Mn +Ofn +Ocn − Hys > Thresh2 (Entering condition)
Ms − Hys > Thresh1 OR Mn +Ofn +Ocn + Hys < Thresh2 (Leaving condition)
Ms − Hys > Thresh1 OR Mn +Ofn +Ocn + Hys < Thresh2 (Leaving condition)
Ms (dBm, dB) is the measurement result of the serving cell, not taking into account any cell individual offset.
Hys (dB) is the hysteresis parameter for this event (i.e. hysteresis as defined within the VarMeasurementConfiguration for this event)
Thresh (dBm, dB) is the threshold parameter for this event (i.e. a1/a2/a4-Threshold as defined within the VarMeasurementConfiguration for this event)
Mn (dBm, dB) is the measurement result of the neighboring cell.
Ofn is the frequency specific offset of the frequency of the neighbor cell (equals Ofs for intra-frequency measurements and is included in MeasObjectEUTRA corresponding to the inter frequency as offsetFreq for inter-frequency measurements)
Ocn is the cell specific offset of the neighbor cell. If not configured zero offset shall be applied (included in MeasObjectEUTRA of the serving frequency as parameter cellIndividualOffset for intra-f measurements and included in MeasObjectEUTRA corresponding to the inter frequency as parameter cellIndividualOffset for interfrequency measurements).
Ofs (dB) is the frequency specific offset of the serving frequency (i.e. offsetFreq within the MeasObjectEUTRA corresponding to the serving frequency)
Ocs (dB) is the cell specific offset of the serving cell (included in MeasObjectEUTRA of the serving frequency as parameter cellIndividualOffset)
Off (dB) is the offset parameter for this event (i.e. a3-Offset as defined within the VarMeasurementConfiguration for this event)
Thresh1 is the threshold parameter for this event (i.e. a5-Threshold1 as defined within the VarMeasurementConfiguration for this event)
Thresh2 is the threshold parameter for this event (i.e. a5-Threshold2 as defined within the VarMeasurementConfiguration for this event)
Tidak ada komentar:
Posting Komentar