Minggu, 10 Mei 2015

SIB3: Cell-reselection parameters for INTRA-Frequency, INTER-Frequency and Inter-RAT



SIB3: Cell-reselection parameters for INTRA-Frequency, INTER-Frequency and Inter-RAT
  • contains Cell re-selection information common for intra-frequency, inter-frequency and inter-RAT cell re-selection (i.e. applicable for more than one type of cell re-selection but not necessarily all)
  • intra-frequency cell re-selection information other than neighbouring cell related
Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE

Important contents of SystemInformationBlockType3
cellReselectionInfoCommon   q_Hyst
     speedStateReselectionPars_exist
cellReselectionServingFreqInfo   s_NonIntraSearch
     threshServingLow
     cellReselectionPriority
intraFreqCellReselectionInfo   q_RxLevMin
     s_IntraSearch
     presenceAntennaPort1
neighCellConfig
p_Max
Field Descriptions:
cellReselectionInfoCommon
Cell re-selection information common for cells
    q_Hyst
This specifies the hysteresis value for cell re-selection ranking criteria. The specified value is added to the serving cell RSRP measurement.
    speedStateReselectionPars
Speed dependent reselection parameters. If this field is absent then mobility State Parameters is not present. If q_hystSF is present then it is added to q_hyst. Carrier (-) value so as to reduce the ranking of the serving cell and allows cellreselection to occur easily.
cellReselectionServingFreqInfo
Information for Cell re-selection to inter-frequency and inter-RAT cells
    s_NonIntraSearch
#used to trigger Interfrequency and IRATfrequency measurements for cell reselection when:
- TARGET Interfreq. has lower or equal priority
- IRAT freq. has a lower priority
# specifies the Srxlev threshold (in dB) for E-UTRAN inter-frequency and inter-RAT measurements.
#If the field s-NonIntraSearchP is present, the UE applies the value of s-NonIntraSearchP.
# Otherwise if neither s-NonIntraSearch nor s-NonIntraSearchP is present, the UE applies the (default) value of infinity for SnonIntraSearchP.
    threshServingLow
This specifies the Srxlev threshold (in dB) below which the serving cell must fall before reselecting towards a lower priority RAT/ frequency. Value in between 0-31dB. Actual value=signalled value*2
    cellReselectionPriority
explains the absolute priority of the concerned serving cell frequency /set of frequencies (GERAN)/ bandclass (CDMA2000), as used by the cell reselection procedure. Corresponds with parameter "priority". Value is between 0-7 where 0 means: lowest priority.
intraFreqCellReselectionInfo
Cell re-selection information common for intra-frequency cells
    q_RxLevMin
Minimum required RSRP for cell reselection. value -70 - 22 dbm, Actual value=signalled value*2
    s_IntraSearch
# used to trigger intrafreq. measurements
# specifies the Srxlev threshold (in dB) for intra-frequency measurements.
# If the field s-IntraSearchP is present, the UE applies the value of s-IntraSearchP instead. Otherwise if neither 09s-IntraSearch nor s-IntraSearchP is present, the UE applies the (default) value of infinity for SIntraSearchP.
    presenceAntennaPort1
is used to09 indicate whether all the neighbouring cells use 09Antenna Port 1.  When set to TRUE, the UE may assume that at least two cell-specific antenna ports are used in all neighbouring cells.
neighCellConfig
used to provide the information related to MBSFN and TDD UL/DL configuration of neighbour cells.
t_ReselectionEUTRA
# specifies the cell reselection timer value
# defines time to trigger for cell reselection
# The parameter can be set per E-UTRAN frequency
p_Max
# max. allowed UL transmit power for intra-frequency neighbouring E-UTRA cells. If absent the UE applies the maximum power according to the UE capability

System Information Block Type2



SIB-2: an IMPORTANT SIB
  • The IE SystemInformationBlockType2 contains radio resource configuration information that is common for all UEs.
  • It carries Common and shared channel configuration, RACH related configuration, Timers, UL Power controls.
  • Without this SIB UE cannot initiate ATTACH procedure.
  • SIB2 is not specifically included in the scheduling information in SIB1 but it is always mapped to the SI message that corresponds to the first entry in the list of SI messages in schedulingInfoList in SIB1
Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE  
Important contents of SystemInformationBlockType2
rach_ConfigCommon
radioResourceConfigCommon
  numberOfRA_Preambles
    preamblesGroupAConfig_exist
    powerRampingParameters
    powerRampingStep
    preambleInitialReceivedTargetPower
    ra_SupervisionInfo
    preambleTransMax
    ra_ResponseWindowSize
  mac_ContentionResolutionTimer
  maxHARQ_Msg3Tx 4
bcch_Config
pcch_Config
prach_Config
pdsch_ConfigCommon
pusch_ConfigCommon
pucch_ConfigCommon

soundingRS_UL_ConfigCommon
uplinkPowerControlCommon
ue_TimersAndConstants
freqInfo
timeAlignmentTimerCommon
   
Field Descriptions:
ac-BarringInfo
Access Class Barring configuration
radioResourceConfig
used to specify common radio resource configurations in the system information and in the mobility control information
 numberOfRA_Preambles
Number of non-dedicated random access preambles
  preamblesGroupAConfig_exist
Provides the configuration for preamble grouping. If the field is not signalled, the size of the random access preambles group A is equal to numberOfRA-Preambles
  powerRampingParameters 

  powerRampingStep
Power ramping factor
  preambleInitialReceivedTargetPower
Initial preamble power
  ra_SupervisionInfo

  preambleTransMax
Maximum number of preamble transmission
 ra_ResponseWindowSize
Duration of the RA response window. Value in subframes. Value sf2 corresponds to 2 subframes
 mac_ContentionResolutionTimer
Timer for contention resolution. Value in subframes. Value sf8 corresponds to 8 subframes
 maxHARQ_Msg3Tx 4
Maximum number of Msg3 HARQ transmissions, used for contention based random access
bcch_Config

 modificationPeriodCoeff
Actual modification period, expressed in number of radio frames= modificationPeriodCoeff * defaultPagingCycle. n2 corresponds to value 2
pcch_Config

 defaultPagingCycle
Default paging cycle, used to derive ‘T’. Value rf32 corresponds to 32 radio frames
 nB
is used as one of parameters to derive the Paging Frame and Paging Occasion
prach_Config
used to specify the PRACH configuration in the system information and in the mobility control information
 rootSequenceIndex

  prach_ConfigIndex
mentions the:
Preamble format: 0-4 (For frame structure 1 preamble format is 0-3 and for frame structure 2 it is 0-4)
SFN: whether it will be EVEN no. frmae OR any frame
subframe number: carrier the subframe no. within the SFN
(Look for the table in TS36.211 - Table 5.7.1-2)
  highSpeedFlag
TRUE corresponds to Restricted set and FALSE to Unrestricted set
  zeroCorrelationZoneConfig
used for Preamble generation
pdsch_Config
used to specify the common and the UE specific PDSCH configuration
pusch_Config
used to specify the common PUSCH configuration and the reference signal configuration for PUSCH and PUCCH
pucch_Config
used to specify the common and the UE specific PUCCH configuration
 soundingRS_UL_Config
used to specify the uplink Sounding RS configuration
uplinkPowerControl
used to specify parameters for uplink power control in the system information and in the dedicated signalling
ue_TimersAndConstants   
Timer values
freqInfo   
UL carrier frequency and bandwidth
timeAlignmentTimerCommon 
used to control how long the UE is considered uplink time aligned. Value in subframes

SIB1 in LTE

The first SIB: SIB1
SIB1 contents assist the UE when it is evaluating cell access and also defines the scheduling of other system information.

Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE
  • SIB1 is broadcasted at every 80 ms and is repeated are mabe within 80ms
  • The first transmission is made at SubFrame 5 for which SFN mod 8 = 0
  • Repetitions are scheduled in SubFRame 5 for which SFN mod 2 = 0
Important contents of SystemInformationBlockType1
cellAccessRelatedInfo   
  PLMN_Identity
     mcc[0] 
     mcc[1] 
     mcc[2] 
     mnc[0] 
     mnc[1] 
 cellReservedForOperatorUse
 trackingAreaCode
 cellIdentity
 cellBarred 
intraFreqReselection 
cellSelectionInfo
    q_RxLevMin 
    q_RxLevMinOffset  
p_Max 
freqBandIndicator 
schedulingInfoList[0]
    si_Periodicity 
    sib_MappingInfo[0] 
si_WindowLength 
systemInfoValueTag 
Field Descriptions:
PLMN-IdentityConsists of MCC and MNC. The first listed one is the Primary PLMN
p-MaxValue applicable for the cell. If absent the UE applies the maximum power according to the UE capability. If eNB configures the value more than the value supported by the UE then UE will set the max value aupported by the UE capability. Example UE Catagory 3 supports max 23 db
cellReservedForOperatorUse As defined by operator (Reserved/Not_reserved)
trackingAreaCode   TAC which is common to the PLMN Identities
cellIdentity    Identifies a cell within the PLMN
cellBarred  If Barred then UE is not allowed to camp on the cell
intraFreqReselection If enabled, UE will be able to perform Cell-reselection to INTRA-frequency cells
q_RxLevMin  Minimum required RX level in the cell 
q_RxLevMinOffsetActual value Qrxlevminoffset = IE value * 2 [dB]. only applied when a cell is evaluated for cell selection as a result of a periodic search for a higher priority PLMN while camped normally in a VPLMN [5]. During this periodic search for higher priority PLMN the UE may check the S criteria of a cell using parameter values stored from a different cell of this higher priority PLMN. Affects the minimum required Rx level in the cell.
freqBandIndicatorindicates the E-UTRA operating band
schedulingInfoListinformation regarding the presence of SIB type; other than SIB1
  si_PeriodicityPeriodicity of the SI-message in radio frames (SI will be transmitted within the specified radio frame)
  sib_MappingInfocarries the List of the SIBs mapped. SIB2 is always present in the first element of schedulingInfoList
  si_WindowLengthspecifies that a SIB should be transmitted somewhere within the specified window length. Value is in ms. This window starts at the starting sub-frame of the mentioned si_periodicity. SIBs can be received in any of the sub-frame as mentioned in the WindowLength.
systemInfoValueTagindicates if a change has occurred in the SI messages. UEs may use systemInfoValueTag, e.g. upon return from out of coverage, to verify if the previously stored SI messages are still valid.
Additionally, the UE considers stored system information to be invalid after 3 hours from the moment it was successfully confirmed as valid, unless specified otherwise.
Common for all SIBs other than MIB, SIB1, SIB10, SIB11 and SIB12.

Jumat, 01 Mei 2015

Pengaruh Modulasi Adaptif Coding (AMC) Untuk Perencanaan Coverage femtocell LTE di AKATEL Purwokerto

Pada penelitian ini digunakan tiga skema modulasi yang berbeda untuk mengetahui pengaruhnya terhadap cakupan didalam ruangan, modulasi tersebut yaitu QPSK, 16QAM, dan 64QAM serta dengan membandingkan dua frekuensi yang digunakan yaitu 700MHz dan 2600MHz. Untuk propagasi yang digunakan dalam perhitungan yaitu menggunakan propagasi Cost 231 Multiwall Model yang memperhitungkan loss dinding agar hasil yang dicapai pada perhitungan dapat disesuaikan dengan kondisi di lapangan.. Hasil dari penelitian tersebut ditunjukkan hasil coverage dan jumlah femtocell yang dibutuhkan dengan melihat pengaruh modulasi adaptif coding yang dihasilkan dan membandingkan kedua frekuansi yaitu pada frekuensi 700MHz coverage yang dihasilkan yaitu 409,6691 m2 dan jumlah femtocell sebanyak 6 femtocell BS. Serta pada frekuensi 2600MHz coverage yang dihasilkan yaitu 29,6965 m2 dan jumlah femtocell sebanyak 72 femtocell BS. Dengan modulasi yang digunakan adalah 64QAM dengan code rate 4/5