SIB11: ETWS secondary notification




  •  contains an ETWS secondary notification

Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE

Important contents of SystemInformationBlockType11
messageIdentifier
serialNumber
warningMessageSegmentType
warningMessageSegmentNumber
warningMessageSegment
dataCodingScheme


Field Descriptions:
messageIdentifier
Identifies the source and type of ETWS notification (earthquake, tsunami warning, any emergency or test message)
serialNumber
Identifies variations of an ETWS notification.
-uses various mechanisms to alert the user (display message, play a tone or vibrate, location where the message is applicable, also contains an update number which specifies whether a change is in the message content or not)
warningMessageSegmentType
[last/not last]
Indicates whether the included ETWS warning message segment is the last segment of the complete segment or not
warningMessageSegmentNumber
# allows oedering of the message segments
# Segment number of the ETWS warning message segment contained in the SIB. A segment number of zero corresponds to the first segment, one corresponds to the second segment, and so on
warningMessageSegment
carries actual segment of the message
dataCodingScheme
Identifies the alphabet/coding and the language applied variations of an ETWS notification

SIB10: ETWS primary notification




  • contains an ETWS primary notification

Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE

Important contents of SystemInformationBlockType10
messageIdentifier
serialNumber
warningType
warningSecurityInfo



Field Descriptions:
messageIdentifier
Identifies the source and type of ETWS notification (earthquake, tsunami warning, any emergency or test message)
serialNumber
Identifies variations of an ETWS notification.
-uses various mechanisms to alert the user (display message, play a tone or vibrate, location where the message is applicable, also contains an update number which specifies whether a change is in the message content or not)
warningType
# Identifies the warning type of the ETWS primary notification (earthquake, tsunami, etc.) and
# provides information on emergency user alert and UE popup
warningSecurityInfo
# is optional, only applied when security is applied
# Provides security information for the ETWS notification

SIB9: Home eNB name




  • contains a home eNB name (HeNB Name)
  • HeNB provie services to Closed Subscriber Groups. The HeNB name helps the user to select the correct CSG Identity when performing a manual selection
Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE

Important contents of SystemInformationBlockType9
hnb-Name


Field Descriptions:
hnb-Name
Carries the name of the home eNB

SIB7: Cell-reselection parameters INTER RAT Frequency (GERAN)




  • contains information relevant only for inter-RAT (GERAN) cell re-selection 
Signalling radio bearer: N/A
RLC-Mode: TM
Logical channel: BCCH
Direction: E‑UTRAN to UE

 
Important contents of SystemInformationBlockType7
t_ReselectionGERAN
Time to trigger for reselection. Value 0 to 7 sec.
carrierFreqsInfoList[0]
carries upto 16 instances of GERAN freq.
carrierFreqs

startingARFCN
Start of the ARFCN
bandIndicator
dcs1800 or pcs1900
followingARFCNs
ARFCN groups
cellReselectionPriority
absolute priority of the GERAN layer. Value 0 to 7, whereas 0 is the lowest priority
ncc_Permitted
Network Color Code. Is a bitmap value
q_RxLevMin
minimum RSSI value required
p_MaxGERAN
maximum allowed UL transmit power
threshX_High
# Threshold (in dB) used by UE for cell re-selection to a HIGHER priority frequency
#  The Srxlev of the candiate cell is greater then threshX_High
# Value 0 to 31 dB. Actual value= Signaled value * 2
threshX_Low
# Threshold (in dB) used by UE for cell re-selection to a LOWER priority frequency
#  Cell re-selection is allowed only when Srxlev of the candiate cell is greater then threshX_Low and RSRP of serving cell is less than the value of ThreshServingLow singalled within SIB3
# Value 0 to 31 dB. Actual value= Signaled value * 2